About Diesel Fired Steam Boiler
Our 1994 established company manufactures and exports Diesel fired steam boiler, that is powerful and highly efficient. Industries that can use this steam boiler are many, for instance textile, garment and paper mill. All components used in the steam boiler are of high grade.
Features of Diesel Fired Steam Boiler:
- This steam boiler consumes low fuel and power.
- It has user friendly controls
- Maintenance is minimal and easy
- Noise doesnt disturb other operations
Technical details
| Dimensions | 32 x 56 x 37 inches |
| Water Feed Pump Power | 1 HP |
| Steam Output | 80 kg/h |
| Fuel Consumption | 3.0 Litres per hour |
| Dry Weight | 510 kg |
Specifications:
- This Steam Boiler can work at wattage of less than 300 watts.
- It worked on reverse flame technology, causing flame and gases to reverse in air tight chamber and the process.
- It causes combustion, best use of energy and output efficiency of 90%.
- It is created with seamless shell and tube.
- The fully automatic equipment is based on a simple shell and seamless technology.
- In an hour, it consume fuel from 2.0 Ltrs. to 4.5 Ltrs. per hour.
- It can be installed in the finishing hall without heating effect.
| Model | Steam Output (Kg/Hour) | Water Feed Pump (H.P.) | Dimensions (W x D X H) inches | Application (No. Of Iron) | Dry Weight (Kgs) | Fuel Consumption (Kg/Hr) |
| DST-30 | 30 | 1 | 32 X 56 X 37 | 6 | 310 | 1.5 - 2 Ltr. |
| DST-50 | 50 | 1 | 32 X 58 X 37 | 12 | 455 | 2.5 - 3.0 Ltr. |
| DST-80 | 80 | 1 | 32 X 62 X 37 | 18 | 510 | 3.0 - 4.0 Ltr. |
| DST 100 | 100 | 1 | 36 X 68 X 40 | 22 | 560 | 4.0 - 4.5 Ltr. |
Reliable Steam Generation for Industrial ApplicationsThe Diesel Fired Steam Boiler is suited for diverse industrial environments needing continuous and dependable steam production. Its horizontal design and advanced combustion system support efficient performance, while the high heat efficiency ensures reduced operational costs. This boiler is built using premium mild steel, providing maximum durability even under demanding conditions. Supported by a robust structure and modern automation features, it is ideal for factories and plants requiring steady steam output.
Maximized Efficiency with Advanced TechnologyWith an efficiency rating of 88%, this boiler is engineered to minimize fuel consumption and environmental impact. The 6.8 liters per hour diesel consumption ensures cost-effective operation, and its design caters to safety, ease of use, and straightforward maintenance. Operating at a reliable pressure of 10.54 Kg/cm2, it meets demanding industrial steam requirements, while its automated controls help optimize performance for any industrial setting.
FAQs of Diesel Fired Steam Boiler:
Q: How does a diesel fired steam boiler generate steam?
A: A diesel fired steam boiler combusts diesel fuel inside a combustion chamber, producing heat that raises the temperature of water within the boiler. This heating process converts the water into steam, which is then directed to various applications as required.
Q: What are the primary benefits of using a diesel fired steam boiler in industrial settings?
A: Key benefits include high heat efficiency (88%), reliable steam production at 1000 kg/hr, and a robust lifespan of about 15 years. It offers low fuel consumption and is constructed from mild steel for enhanced durability, supporting consistent performance in challenging environments.
Q: When is it suitable to use this particular steam boiler model?
A: This boiler is ideal for new industrial installations where reliable steam generation is necessaryespecially in sectors such as textiles, pharmaceuticals, food processing, or chemical production, where precise temperature and pressure control are vital.
Q: Where can this diesel fired steam boiler be supplied or exported from?
A: The boiler is manufactured, supplied, and exported from India, with services available to both domestic and international industrial clients seeking dependable steam solutions.
Q: What is the typical process for installing and commissioning this steam boiler?
A: Installation generally involves positioning the boiler on a firm, level base, connecting water and fuel inlets, ensuring proper electrical wiring for the 230 V supply, and integrating with the steam output system. Commissioning includes safety checks, calibration, and performance testing, usually handled by certified technicians.
Q: How should this boiler be used and maintained for optimal efficiency?
A: Regularly check fuel, water, and safety controls, clean heat exchanger surfaces, and monitor for leaks to maintain performance. Routine professional servicing helps sustain its 88% efficiency and maximize its 15-year lifespan.
Q: What capacities and technical specifications set this boiler apart?
A: With a capacity to deliver 1000 kg/hr of steam at 10.54 Kg/cm2, a heat efficiency of 88%, and a compact design (3850 x 1800 x 2100 mm), this horizontal boiler stands out for its durable construction, energy-saving operation, and modern automation.